-- “----‘I u SYSTEM BOILER Central Heating Faned Flue system Installation and System 40 Operating instructions System 60 “heygFJ& v AA
Weights With packaging : -BRITONY SYSTEM 40 : -BRITONY SYSTEM 60 : Without packaging : -BRITONY SYSTEM 40: -BRITONY SYSTEM 60 : Lift we
Minimum clearances : - Both sides 5mm - Above casing 170 mm - Below casing 200 mm - Front ( for servicing) 500 mm - Frdnt (in operation) 5 m
25 Fig. 6 20 Central Heating To be able to supply heating, the selector switch 19 fig. 6 must be turned fully clockwise to ‘ffff po
After 45 seconds the second stage solenoid 12b fig. 7 opens to allow the full gas rate. If a flame is not detected, after 8 seconds
Location - F From an internal or external corner 300 mm - G Above ground roof or balcony level 300 mm The boiler can be installed on
It may be necessary to protect the terminal with a guard if it is accessible and could be damaged. Reference should be made to the Build
Please check that you are familiar with the installation requirements before commencing work.(section 6) Installation The installation k
boiler. Using fig. 15 for reference, connect the gas and water pipes to the valves located at the base of the appliance using the
Connecting of the boiler to the system - Hinge down the electrical box to gain access to the valves connections. Push in the tabs
Making the Electrical Connections Hinge down the electrical box to gain access to the electrical connections. Push in the tabs (P f
These instructions are suitable for the following boilers : Britony System 40 Britony System 60
connector C 1 2 Fig. 20 If using a room thermostat or other external control, they can be connected in place of the link on the multipin
Pre-commissioning Ensure that the system has been adequately flushed. Purge gas supply of air and test for soundness. Carry out final e
43 - 19 \ 21 - / /6 Fig. 23 Turn the boiler thermostat to maximum (21 fig 23). The boiler will light. Allow the boiler to heat system.
The boiler is suitable for sealed systems only. The maximum working pressure for the appliance is 3 bar. All fittings and pipework
By pass and Pump The boiler is fitted with a pre-adjusted by pass. Although adjustment is not normally necessary, the by pass can
Expansion Vessel Filling Point The expansion vessel is pre-charged to 0.7 bar (10 Ib/in2). Provision must be made to be able to charge
Control panel 19. Two position Selector switch l = Switched OFF ‘Ill1 = Central heating 20. User’s instruction panel. 21. ‘Ill1 Heating flow te
Switching on Note: If the boiler has been turned off for some time the first attempt to light it may result in a lockout 4. If this 1) C
Chaffoteaux et Maury are continuously improving their products and therefore reserve the right to change specifications without prior
CUSTOMER CARE Chaffoteaux et Maury Ltd , as a leading manufacturer of domestic and commercial water heating appliances, is committed
Page 3 3 3 4 5 6 6 8 10 12 12 14 14 14 15 15 15 16 16 17 19 Page CUSTOMER CARE.. ... Guarantee.. ...
The BRITONY SYSTEM is a fully automatic, wall mounted, low water content boiler. It is a room sealed, fan assisted, balanced flued
Location of components 1. Air pressure switch 2. Steel chassis complete with expansion vessel 3. Main heat exchanger 4. Combustion chamber 5.
- 18' 27' 29' 26. Pressure gauge 27. Gas service tap 29. CH Return isolating valve 30. Pressure relief valve 32. By pass 33. By pas
BRITONY SYSTEM type Appliance category . . . . . . . . . . . . . . . . . . . . . Heat input C/H Maximum in kW . . . . . . . . . . . . . . . .
BRITONY SYSTEM type 40 BUTANE L.P.G. G30 Gas rate Maximum in kg/h . . . . . . . . . . . . . . . . . . . 1.05 1.58 Maximum in Lbslh . . . .